Heat Pumps > Products and Installation > HRV > Fantech > SHR 3005R HRV

 

SHR 3005R HRV

  • Airflow up to 253 cfm @ 0.4″ PS serves 3-7 bedroom homes
  • External dry contacts for quick connection of remote controls
  • Easy access service door

Application

The SHR 3005R’s double core configuration provides the greater thermal efficiency needed for homes being built to a higher energy standard.

How it works

The incoming air passes through a first, then a second heat exchanger to provide maximum heat recovery. During winter, fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs, while during summer, the incoming air is pre-cooled if the house is equipped with an air cooling system.

Defrost cycle

During the defrost sequence, a motorized damper temporarily blocks the incoming fresh air stream so that the warm air from the house can circulate through the HRV. The exhaust blower shuts down and the supply blower switches into high speed to maximize the effectiveness of the defrost strategy. During this cycle, household odors from the kitchen or bathroom are prevented from entering the home and the unit will not create negative pressure.

Warranty

  • 10 Years on Compressor
  • 5 Years on Parts
  • One Touch 1 Year Labour
  • 10 Years Compressor, Parts and Labour Available